CurrentClampAccuracy
DCA range: 1mV/10mA
± (2.0%±5mA) 10mA~20A
DCA range: 1mV/100mA
± (2.0%±20mA) 100mA~40A
± (4.0%±0.3A) 40A~60A
ACA range: 1mV/10mA
±(2.0%±5mA) 10mA~10A (40Hz~2kHz)
±(4.0%±30mA) 10mA~10A (2kHz~10kHz)
±(6.0%±30mA) 10mA~10A (10kHz~20kHz)
±(8.0%±30mA) 10A~15A (40Hz~20kHz)
ACA range: 1mV/100mA
±(2.0%±30mA) 100mA~40A (40Hz~1kHz)
±(4.0%±30mA) 100mA~40A (1kHz~2kHz)
±(6.0%±30mA) 100mA~40A (3kHz~5kHz)
±(8.0%±0.3A) 40A~60A (40Hz~5kHz)
Temperature Coefficient: 0.1x(specified accuracy) per
degree C. (0°C to 18°C, 28°C to 40°C)
Source: SA